Moulded Case Residual Current Circuit Breaker (GNM2L)

Moulded Case Residual Current Circuit Breaker (GNM2L)
Moulded Case Residual Current Circuit Breaker (GNM2L)

Product Description

Application
GNM2L series moulded case residual current circuit breaker (hereinafter refer to as circuit breaker )is widely used in AC power distribution of which frequency is 50Hz, rated voltage 400V and rated current up to 630A. It can protect the wire and power supply from overload, short circuit and under-voltage, and also function as nonfrequent switch for wire under normal condition. The circuit breaker has function of protecting human body from eletric shock and equipment from electrical leakage, still also, it can prevent fire caused by insulation problem of equipment.

Remarks:
1. No code for current distribution; 2 means for motor protection.
2. Hand lever direct operating with no code: P represents electric
Motor operating; Z repressent turning hand lever.

Structure and working principle
The circuit breaker is of electronic type. It is mainly composed of a zero-sequence Current transformer electronic-controlled redisual current-tripping gear and break with overload and short-circuit protection. All components and parts assembled in a plastic casing.

If current leaks from a protected circuit or a person gets an electric shock, as long as the leakage current reaches the action current value, a signal will be sent out from the secondary coil of the zero sequence current transformer. The signal will cause the breaker to switch off the power supply with the help of a leakage tripping gear so as to fulfill the leakage or the electric shock protection.

Working condition
The altitude of the installation place shall not exceed 2000m.
The upper limit of the environmental temperature is +40ºC.
The lower limit of the temperature is 5ºC.
The average temperature in 24 hours shall not exceed +35ºC.
The relative humidity shall not exceed 50% when the environmental temperature is +40ºC. The relative humidity may be higher at the lower temperature condition. The maximum month-average relative humidity is 90% in the most humid month with a minimum month-average temperature+25ºC. The factor that dew may occur on the product surface due to temperature change shall be taken into consideration.

Installation condition
The residual current breaker shall be installed in a rainproof place without shock and vibration.
The upper wiring terminal shall be connected to the power supply side and the lower wiring terminal to the load side.
The incline to the vertical plane shall not exceed 5ºC.
The external magnetic field intensity nearby the installation of the leakage breaker shall not exceed five times as much as the earth magnetic field intensity in any direction.

Type In(A)
Rated current
Ue(V)
Rated
voltage
Ui(V)
Rated insulated
voltage
(Hz)
Rated
frequency
Pole lcu/cosφ
Breaking capactiy
of rated maximal
short circuit
Lcs/cosφ
Breaking capacity
of rated working
short circuit
Rated residual
action currentI  n(mA)
Rated residual
inaction currentI  no(mA)
GNM2L-100M 16,20,25,32
40,50,63,80
100
AC400 AC800 50 3,4 35kA/0.25 22kA/0.25 30/100/500
100/300/500
15/50/250
50/150/250
GNM2L-100H 50kA/0.25 35kA/0.25
GNM2L-225M 100,125,140
160,180,200
225
35kA/0.25 22kA/0.25
GNM2L-225H 50kA/0.25 35kA/0.25
GNM2L-400M 225,250,315
350,400
4 65kA/0.2 42kA/0.25
GNM2L-400H 400,500,630 4 300/500/1000 150/250/500